Allen-Bradley 1734-IB8S

✓ In Stock

Manufacturer: Allen Bradley - PLC
Product Type: PLC/Programmable Logic Controller
Part Number: 1734-IB8S
Series: Point I/O 1734
UPC: 10612598350619

Description:

The 1734-IB8S is a POINT Guard I/O Safety Module by Allen-Bradley and Rockwell Automation. It has 8 inputs per module and a current sinking input type. This hardware has a maximum off-state input voltage of 5 Volts DC.



Automation Stop is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with Automation Stop's 1-year warranty.

Original Packaging

$539.00

Available: 2

What is Original Packaging

Your order will ship by . Need it faster?

Refurbished

$285.00

Available: 2

What is Refurbished

Your order will ship by . Need it faster?

Repair Service

$228.00

2-4 Weeks

What is Fast Repair

Repair Completion:
2-4 Weeks
Need it faster?

Looking for a 1734-IB8S? We can help!

Request a Quote

  Pay

We accept credit cards from all major providers, as well as PayPal.

  Ship

We offer worldwide shipping with UPS and DHL.

  Warranty

We proudly offer a one year Automation Stop warranty on most products.

The 1734-IB8S is a POINT Guard I/O Safety Module by Allen-Bradley and Rockwell Automation. It has 8 inputs per module and a current sinking input type. This hardware has a maximum off-state input voltage of 5 Volts DC. On-state input voltage for the 1734-IB8S is 11…30 Volts DC, 3.5 milliAmps at 40 degrees Celsius and 11…28.8 Volts DC, 3.5 milliAmps at 55 degrees Celsius. It has a minimum on-state input current of 3.3 milliAmps and a maximum off-state current of 1.3 milliAmps. The IEC 61131-2 input type is Type 3 and it has a current sourcing output type. With regard to output, this hardware has 4 sources (T0, T1M, T2, T3M). The aggregate current of test outputs per module are 2.8 Amps at 40 degrees Celsius and 0.55 Amps at 55 degrees Celsius. It has a pulse period of 144 milliseconds and a maximum current (when used to control muting lamp) of 25 milliAmps; minimum current when used to control muting lamp is 5 milliAmps.

Additional technical specifications for the 1734-IB8S include a maximum residual voltage of 0.3 Volts and a maximum output leakage current of 0.1 miliAmps. This module is equipped with short circuit protection and has a maximum POINTBus current of 110 milliAmps. Maximum power dissipation is 3.0 Watts and maximum thermal dissipation is 10.25 British Thermal Units (BTU) per hour; typical power dissipation is 2.25 Watts and it has an isolation voltage of 50 Volts (continuous) with basic insolation type. The test outputs for pilot duty rating are not rated. The 1734-IB8S has an approximate weight of 62.4 grams, or 2.2 ounces and approximate dimensions of 77 x 25 x 55 millimeters, or 3.03 x 0.98 x 2.17 inches.

Technical Specifications

Region of Manufacture* United States
Type PLC Input Module
Manufacturer: Allen-Bradley / Rockwell Automation
Inputs per Module: 8
Input Type: Current Sinking
Maximum Off-State Input Voltage: 5 Volts DC
Minimum On-State Input Current: 3.3 milliAmps
Maximum Off-State Current: 1.3 milliAmps
IEC 61131-2 Input Type: Type 3
Output Type: Current Sourcing
Output Sources: T0, T1M, T2, T3M
Pulse Period: 144 milliseconds
Maximum Residual Voltage: 0.3 Volts
Maximum Output Leakage Current: 0.1 milliAmps
Short Circuit Protection: Yes
Maximum POINTBus Current: 110 milliAmps
Maximum Power Dissipation: 3.0 Watts
Maximum Thermal Dissipation: 10.25 British Thermal Units (BTU) per Hour

*Region of Manufacture may vary

We offer UPS shipping. Including Ground, 2nd Day Air, Next Day Air and Early AM. Some of our products have a short lead time, so please contact us if you need any item faster than the lead time shown. If you need to order an item internationally please contact us prior to checking out so we can get you a shipping quote. We can ship UPS or DHL internationally. We can also ship on your UPS or FedEx account number.
If the item is found to be defective within 30 days of the invoice date, a full refund can be issued. If an item is found to be defective through normal use and wear after 30 days but within the 1 year period, the Automation Stop Warranty dictates the appropriate course of action. After the 30 day period, Automation Stop reserves the right to decide between refund, repair, or replacement with identical product. Because of the high volume of outgoing and incoming shipments on a day to day basis, we unfortunately cannot accept returns on items ordered mistakenly or part numbers ordered incorrectly. If a special exception is approved, a 20% restocking fee will be assessed. If you have any questions please contact us at [email protected].

FAQ

Question: Does Automation Stop offer repairs on the 1734-IB8S?

Answer: Yes. We offer repairs for the 1734-IB8S and it comes with our 1 Year Automation Stop Warranty.


Question: What type of warranty comes with the Allen Bradley - PLC and 1734-IB8S?

Answer: If you buy the 1734-IB8S through Automationstop.com it comes with our 1 Year Warranty and no other warranties.


Question: Can I buy the 1734-IB8S online?

Answer: Yes. Automation Stop sells the 1734-IB8S online and you can check out for the quantity and condition listed available above.


Question: What is the manufacturer for the 1734-IB8S?

Answer: The 1734-IB8S is made by Allen Bradley - PLC.


Question: What type of product is the 1734-IB8S?

Answer: The 1734-IB8S is part of the Point I/O 1734 series.


Question: What is the IEC 61131-2 Input Type: of the 1734-IB8S?

Answer: The Allen-Bradley 1734-IB8S has a IEC 61131-2 Input Type: of Type 3.


Question: What Input Type: does the Allen Bradley Automation 1734-IB8S have?

Answer: The 1734-IB8S has a Current Sinking Input Type:.


Question: What is the Inputs per Module: of the Rockwell-Automation 1734-IB8S?

Answer: The Inputs per Module: of the Rockwell-Automation 1734-IB8S is 8.


Question: What Manufacturer: does the Allen Bradley-Rockwell Automation 1734-IB8S have?

Answer: The 1734-IB8S has a AB / Rockwell Automation Manufacturer:.


Question: What Maximum Off-State Current: does the Allen Bradley/Rockwell Automation 1734-IB8S have?

Answer: The 1734-IB8S has a Maximum Off-State Current: of 1.3 milliAmps.


Question: What Maximum Off-State Input Voltage: does the Allen-Bradley 1734-IB8S have?

Answer: The Maximum Off-State Input Voltage: of the Allen-Bradley 1734-IB8S is 5 Volts direct current (DC).


Question: What is the Maximum Output Leakage Current: of the 1734-IB8S?

Answer: The Rockwell Automation 1734-IB8S has a Maximum Output Leakage Current: of 0.1 milliAmps.


Question: What is the Maximum POINTBus Current: of the 1734-IB8S?

Answer: The Allen-Bradley 1734-IB8S has a Maximum POINTBus Current: of 110 milliAmps.


Question: What Maximum Power Dissipation: does the 1734-IB8S have?

Answer: The Allen Bradley/Rockwell Automation 1734-IB8S has a Maximum Power Dissipation: of 3.0 Watts.


Question: What Maximum Residual Voltage: does the 1734-IB8S have?

Answer: The Rockwell-Automation 1734-IB8S has a Maximum Residual Voltage: of 0.3 Volts.


Question: What Maximum Thermal Dissipation: does the 1734-IB8S have?

Answer: The Maximum Thermal Dissipation: of the 1734-IB8S is 10.25 British Thermal Units (BTU) per Hour.


Question: What is the Minimum On-State Input Current: of the Rockwell-Automation 1734-IB8S?

Answer: The 1734-IB8S has a Minimum On-State Input Current: of 3.3 milliAmps.


Question: What is the Output Sources: of the 1734-IB8S?

Answer: The Output Sources: of the 1734-IB8S is T0, T1M, T2, T3M.


Question: What Output Type: does the 1734-IB8S have?

Answer: The Allen Bradley-Rockwell Automation 1734-IB8S has a Current Sourcing Output Type:.


Question: What Pulse Period: does the Rockwell Automation 1734-IB8S have?

Answer: The Pulse Period: of the 1734-IB8S is 144 milliseconds.


Question: What Region of Manufacture* does the Allen Bradley/Rockwell Automation 1734-IB8S have?

Answer: The Allen Bradley/Rockwell Automation 1734-IB8S has a United States Region of Manufacture*.


Question: Does the Allen Bradley Automation 1734-IB8S have a Short Circuit Protection:?

Answer: Yes.


Series information for 1734-IB8S

For additional information about 1734-IB8S check the data sheet or manual. Also check the manual PDF for all wiring diagrams, compatibility, troubleshooting, specifications, installation instructions, and accessories (such as batteries, terminal blocks, or cables) regarding 1734-IB8S.

Revision Part # Also Known As Availability
1734-IB8S/A 1734-IB8S Ser A, Series A, Rev A Request a Quote
1734-IB8S/B 1734-IB8S Ser B, Series B, Rev B Request a Quote

Common Misspellings:

  • 1734-IB85
  • 1734-IBBS
  • 1734-IBB5
  • 1734-I88S
  • 1734-I885
  • 1734-I8BS
  • 1734-I8B5
  • 1734-1B8S
  • 1734-1B85
  • 1734-1BBS
  • 1734-1BB5
  • 1734-188S
  • 1734-1885
  • 1734-18BS
  • 1734-18B5
  • I734-IB8S
  • I734-IB85
  • I734-IBBS
  • I734-IBB5
  • I734-I88S
  • I734-I885
  • I734-I8BS
  • I734-I8B5
  • I734-1B8S
  • I734-1B85
  • I734-1BBS
  • I734-1BB5
  • I734-188S
  • I734-1885
  • I734-18BS
  • I734-18B5

Automation Stop sells used surplus products. Automation Stop is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by Automation Stop come with Automation Stop’s 1-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. Automation Stop is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Automation Stop is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Automation Stop also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Automation Stop also makes no representations as to your right to install any such firmware on the product. Automation Stop will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

TOP