GE / IP FANUC Series 90/30 In Stock

Call Now

(919) 867-5794

Mon-Fri 8AM-5PM EST

Allen-Bradley 1747-L541

✓ In Stock

Manufacturer: Allen Bradley - PLC
Product Type: PLC/Programmable Logic Controller
Part Number: 1747-L541
Series: SLC 500
UPC: 10662468653029

Description:

The Allen-Bradley 1747-L541 module is a controller that belongs to the SLC 500 series of controllers which has a modular design. It features a maximum of 64 kilobytes (kb) of memory and is capable of supporting a maximum of 4096 I/O points. Its I/O scan time is 0.225 milliseconds so the processor is able to form and run not only small, but also medium size applications. This device requires a current load of 1 ampere at 5 volts DC to operate.



Automation Stop is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply. Product comes with Automation Stop's 1-year warranty.

Original Packaging

$5,130.00

Available: 14

What is Original Packaging

Your order will ship by . Need it faster?

Refurbished

$665.00

Available: 121

What is Refurbished

Your order will ship by . Need it faster?

Repair Service

$532.00

2-4 Weeks

What is Fast Repair

Repair Completion:
2-4 Weeks
Need it faster?

Looking for a 1747-L541? We can help!

Request a Quote

Key Features:

  • is a slc 5/04 processor
  • supports dh+, rs-232 for communication

  Pay

We accept credit cards from all major providers, as well as PayPal.

  Ship

We offer worldwide shipping with UPS and DHL.

  Warranty

We proudly offer a one year Automation Stop warranty on most products.

The 1747-L541 is an SLC 504 or SLC 5/04 processor manufactured by Allen Bradley/Rockwell Automation as part of the SLC 500 series, which also comprises of the 1747-L541, L542, and L543 processors. This is a high-performance processor improved with shorter program execution and faster communication time. It requires a backplane current load of 200 milliamps at 24 volts DC and 1 ampere at 5 volts DC, with a 1-millisecond selectable timed interrupt (STI) as well as discrete input interrupt (DII) of 0.5 milliseconds. This module has a flash-based memory device of 64 kilobytes for storage of programs and data table, and it comes with RS-232 channel that supports DF1 radio modem, ASCII, Modbus RTU, and DH-485 communications. It features advanced math instructions as well as different additional instructions. This module supports remote input and output, DeviceNet pass-through, as well as indirect addressing. Allen Bradley SLC 504 series, including 1747-L541 processor, has 16, 32, or 64 keywords of memory and can control up to 4096 output and input points. The 1747-L541 processor features an inbuilt DH+ channel that supports advanced messaging capabilities as well as high-speed communication. This processor has a typical program scan time of 0.9 milliseconds per keyword and a typical input and output scan time of 0.225 milliseconds. The SLC 504 series has a 3-position key switch on the front for selecting between the remote, program, or run modes. The 1747-L541 SLC 504 processor comes with BATT, RUN, FLT, RS-232 FORCE, and DH+ LED status indicators to enhance diagnostics and troubleshooting. The SLC 500 processors have a simple, cost-effective design and support installation in applications including SCADA, HVAC control, and material handling.

Part number 1747-L541 belongs to the SLC 500 series of processors that were manufactured by Allen-Bradley and there are several versions that have a maximum memory of 64 kb (kilobytes). This processor supports a modular architecture of I/O modules, in other words, the modular design and the maximum controlled I/O points is 4096. The processor supports ladder program that should be entered in its memory using RS-232 interface, usually, although the processor is supporting DH-485, DF1 and modbus communications (there is a built-in RS-232/422/423 communication port). The switch on the panel can select the run, remote, or program modes and after programming, which is a proprietary process, the programmer just put the switch in run position. After that start up, the processor can scan program instruction and the typical I/O scan time is 0.225 milliseconds. According to the modular design, all input and output modules are located next to the processor module and also there is a power supply for all of them. The processor itself has an advanced instruction set that includes file handling, sequencing, diagnostics, shift register, advanced math instructions, immediate I/O, and program control instructions. The 1747-L541 can support several types of that modules such as digital, analog, and special combination modules but it supports also the remote I/O and it has a built-in DH+ channel for high-speed communication. All voltages and signals of this device are on the backplane. Therefore, this unit requires a current load of one (1) ampere at 5 (five) volts direct current (DC).

Technical Specifications

Brand Allen Bradley/Rockwell Automation
Series SLC 500
Part Number 1747-L541
Module Type SLC 5/04 Processor
Inputs 4096
Outputs 4096
Analog I/O 480
Communication DH+, RS-232
Backup Memory Flash
I/O Chassis 3
Region of Manufacture* United States
UNSPSC 32151705
Type PLC Processor Module

*Region of Manufacture may vary

We offer UPS shipping. Including Ground, 2nd Day Air, Next Day Air and Early AM. Some of our products have a short lead time, so please contact us if you need any item faster than the lead time shown. If you need to order an item internationally please contact us prior to checking out so we can get you a shipping quote. We can ship UPS or DHL internationally. We can also ship on your UPS or FedEx account number.
If the item is found to be defective within 30 days of the invoice date, a full refund can be issued. If an item is found to be defective through normal use and wear after 30 days but within the 1 year period, the Automation Stop Warranty dictates the appropriate course of action. After the 30 day period, Automation Stop reserves the right to decide between refund, repair, or replacement with identical product. Because of the high volume of outgoing and incoming shipments on a day to day basis, we unfortunately cannot accept returns on items ordered mistakenly or part numbers ordered incorrectly. If a special exception is approved, a 20% restocking fee will be assessed. If you have any questions please contact us at [email protected].

FAQ

Question: Does Automation Stop offer repairs on the 1747-L541?

Answer: Yes. We offer repairs for the 1747-L541 and it comes with our 1 Year Automation Stop Warranty.


Question: What type of warranty comes with the Allen Bradley - PLC and 1747-L541?

Answer: If you buy the 1747-L541 through Automationstop.com it comes with our 1 Year Warranty and no other warranties.


Question: Can I buy the 1747-L541 online?

Answer: Yes. Automation Stop sells the 1747-L541 online and you can check out for the quantity and condition listed available above.


Question: What is the manufacturer for the 1747-L541?

Answer: The 1747-L541 is made by Allen Bradley - PLC.


Question: What type of product is the 1747-L541?

Answer: The 1747-L541 is part of the SLC 500 series.


Question: What Analog input/output does the 1747-L541 have?

Answer: The Analog input/output of the Allen Bradley/Rockwell Automation 1747-L541 is 480.


Question: What Backup random-access memory (RAM) does the Rockwell-Automation 1747-L541 have?

Answer: The 1747-L541 has a Flash Backup random-access memory (RAM).


Question: What Brand does the Allen Bradley/Rockwell Automation 1747-L541 have?

Answer: The 1747-L541 has a Allen Bradley/Rockwell Automation Brand.


Question: What is the Communication of the 1747-L541?

Answer: The Communication of the Rockwell-Automation 1747-L541 is DH+, RS-232.


Question: What input/output Chassis does the 1747-L541 have?

Answer: The Rockwell Automation 1747-L541 has a input/output Chassis of 3.


Question: What is the Inputs of the 1747-L541?

Answer: The Inputs of the Allen Bradley/Rockwell Automation 1747-L541 is 4096.


Question: What Module Type does the Rockwell-Automation 1747-L541 have?

Answer: The 1747-L541 has a Module Type of SLC 5/04 Processor.


Question: What Outputs does the 1747-L541 have?

Answer: The 1747-L541 has a Outputs of 4096.


Question: What part Number does the Allen Bradley-Rockwell Automation 1747-L541 have?

Answer: The Allen Bradley-Rockwell Automation 1747-L541 has a component Number of 1747-L541 .


Question: What Region of Manufacture* is included with the Rockwell-Automation 1747-L541?

Answer: The Rockwell-Automation 1747-L541 has a United States Region of Manufacture*.


Question: What UNSPSC does the 1747-L541 have?

Answer: The UNSPSC of the Allen Bradley-Rockwell Automation 1747-L541 is 32151705.


Series information for 1747-L541

For additional information about 1747-L541 check the data sheet or manual. Also check the manual PDF for all wiring diagrams, compatibility, troubleshooting, specifications, installation instructions, and accessories (such as batteries, terminal blocks, or cables) regarding 1747-L541.

Revision Part # Also Known As Availability
1747-L541/A 1747-L541 Ser A, Series A, Rev A Request a Quote
1747-L541/B 1747-L541 Ser B, Series B, Rev B Request a Quote
1747-L541/C 1747-L541 Ser C, Series C, Rev C Request a Quote

Common Misspellings:

  • 1747-L54I
  • 1747-LS41
  • 1747-LS4I
  • I747-L541
  • I747-L54I
  • I747-LS41
  • I747-LS4I

Automation Stop sells used surplus products. Automation Stop is not an authorized distributor, affiliate, or representative for the brands we carry. Products sold by Automation Stop come with Automation Stop’s 1-year warranty and do not come with the original manufacturer’s warranty. Designated trademarks, brand names and brands appearing herein are the property of their respective owners. This website is not sanctioned or approved by any manufacturer or tradename listed.

Rockwell Disclaimer: The product is used surplus. Automation Stop is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Automation Stop is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, DO Supply makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Automation Stop also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Automation Stop also makes no representations as to your right to install any such firmware on the product. Automation Stop will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

TOP